More Videos...
 

Optimal Design of High-Order Passive-Damped Filters for Grid-Connected Applications

Optimal Design of High-Order Passive-Damped Filters for Grid-Connected Applications Harmonic stability problems caused by the resonance of high-order filters in power electronic systems are ever increasing. The use of passive damping does provide a robust solution to address these issues, but at the price of reduced efficiency due to the presence of additional passive components. Hence, a new method is proposed in this paper to optimally design the passive damping circuit for the LCL filters and LCL with multi-tuned LC traps. In short, the optimization problem reduces to the proper choice of the multi-split capacitors or inductors in the high-order filter. Compared to existing design procedures, the proposed method simplifies the iterative design of the overall filter while ensuring the minimum resonance peak with a lower damping capacitor and a lower rated resistor. It is shown that there is only one optimal value of the damping resistor or quality factor to achieve a minimum filter resonance. The passive filters are designed, built and validated both analytically and experimentally for verification.